Thursday, October 1, 2015

 061 TESTING CURA SLICER

Keeping  Mininum Layer Time (sec) from 5.0 to 20.0 and changed Minimum cooling Speed (mm/s) from 10.0 to 5.0.



Print time: [00:019:54]   Total Service Hours: [40:31:59]


 060 TESTING CURA SLICER

Same as test [059]. Changed  Mininum Layer Time (sec) from 5.0 to 20.0.



Print time: [00:018:59]   Total Service Hours: [40:12:05]


 059 TESTING CURA SLICER

Testing Cura 15.04.2 with 1.75mm black ABS filament. 5.omm nozzle at 220 c. Using default settings with no changes. Needs cooling.



Print time: [00:012:15]   Total Service Hours: [39:53:06]


 058 TESTING SKEINFORGE SETTINGS

Testing Skeinforge with Durbie profile Filament is 175mm black ABS at 220 c. Test is to compare difference against test [057] Slic3r profile to verify a non-hardware issue. printed OK. Hardware appears fine.



Print time: [00:029:35]   Total Service Hours: [39:40:51]


 057 TESTING SLIC3R SETTINGS

Testing Slic3r 1.2.9.  with 1.75mm black ABS filament. 5.0mm nozzle at 220 c. Using default settings with these changes: Changed Cool slowdown from 5.0 to 15.0. Abort. Not enough filament extruding for pillars.



Print time: [00:007:00]   Total Service Hours: [39:11:16]


 056 TESTING SLIC3R RETRACTION

Testing Slic3r 1.2.9.  with 1.75mm black ABS filament. 5.0mm nozzle at 215 c. Using default settings with these changes: Retraction Length from 2.0 to 1.2 and Retraction Speed from 40.0 to 12.0. No good.



Print time: [00:022:32]   Total Service Hours: [39:04:16]


055 TESTING SLIC3R SETTINGS

Testing Slic3r 1.2.9.  with 1.75mm black ABS filament. 5.0mm nozzle at 215 c. Using default settings with these changes: 15% Infill. Travel speed 50mm/s and Cooling at 15s. Aborted. Possible retraction problem?



Print time: [00:06:00]   Total Service Hours: [38:41:44]